ELECTRICAL |
|
|
. |
|
|
Nominal
Line Input |
220VAC,
1-phase, 50/60 Hz. |
|
AC
Supply Tolerance |
+/-
10% for all types. |
|
Frequency |
47-63
Hz for all types. |
|
Power
Factor (full load) |
>=0.9
better than 0.98 with PFC. |
|
Efficiency |
>=70% |
|
. |
|
|
Output
Ripple (full load) |
0.5%
pk-pk, 1kHz bandwidth. |
|
Line
Regulation |
0.1%
for +/- 10% line voltage change, all types. |
|
Output
Drift |
<=0.1% over 8 hour period. (With constant
temperature, load and line conditions). |
|
. |
|
|
Output
Rating (maximum current) |
Type
1 - 35A, Type 2 - 75A, Type 3 - 100A. |
|
. |
|
|
. |
|
|
MECHANICAL |
|
|
. |
|
|
Size
(mm) - '3U' |
Height
132, Width 483, Depth 390. |
|
|
Note:
add 25mm for connections. |
|
. |
|
|
Weight
(kg) |
9.0 |
|
. |
|
|
Cooling |
Forced
air using internal fan, exiting at the rear. |
|
. |
|
| Temperature |
Continuous in an ambient of 0°C to 60°C with
appropriate derating above 35°C. |
|
. |
|
|
Safety
(all Types) |
All control circuitry and wiring has full galvanic isolation from
the line, and are low voltage. The output is fully floating.
If required, it is recommended that the positive (+)
lead is connected to earth.
The build standards comply with EN61010-1 and conform to the requirements
of the Low Voltage Directive 73/23/EEC and carry the
CE Mark.
An appropriate EMC Filter is fitted. The units comply with the
Emission and Immunity Standards EN50082-2 and EN50081-2
(Class A). A PFC Input is optional.
|
|
Protection |
Protection on the line input is by a line fuse.
Output protection is included in the event of an open
circuit or short circuit load. There is also an over-current
and power limit. Thermal protection is included against
over-temperature.
Output diode current ramp to maximum output is set at approximately
three seconds to prevent thermal shock.
|
| Front
Panel Controls |
Key-switch
for Line power.
ON-OFF Rocker switch.
10-turn potentiometer for lamp current control.
3 1/2 Digit LED Display of lamp current.
Push Switch selecting 'Standby'. Remote or potentiometer
control of output lamp current. |
|
. |
|
|
Rear
Control Connector |
15-way
'D' connector. |
|
. |
|
| Functions
include: |
Interlock
Status
Overtemperature
Remote/Local select of ON/OFF
0-10VDC Diode Current Control
Diode 'ON' output (Answer Back)
Output Monitor Voltage |
|
.. |
|
|
Output
Modulation Optional |
A second 0-10VDC signal can be used to modulate
the output diode current. This has a fast response and
is limited over a smaller range of output diode current.
Its main application is in process control. |
|
. |
|
|
New